Camber (edgebow or sweep)

Standard Camber Tolerances
Strip
Width
Standard
Camber
Equivalent camber limits: in. (mm)
For various strip lengths: ft. (m)
W
in.
(mm)
tolerance
Ct, in/ft
(mm/m)
 
  8 4 6 10 12 16 20
  (2.44) (1.22) (1.83) (3.05) (3.66) (4.88) (6.09)
0.5-1.50 0.50 0.125 0.281 0.781 1.125 2.0 3.125
(12.7-38.1) (12.7) (3.18) (7.14) (19.84) (28.58) (50.8) (79.38)
1.5-13.0 .25 .0625 0.141 0.391 0.563 1.0 1.562
(38.1-330.2) (6.35) (1.59) (3.58) (9.93) (14.30) (25.4) (39.68)

If camber is measured over a strip length not shown in table above, it can be easily converted to an equivalent value for comparison with the standard tolerance, using the formula:

Cu = Ck x (Lu / Lk)2
   
where Cu = Unknown Camber
  Ck = Known Camber
  Lu = Unknown Length
  Lk = Known Length

Standard Camber Tolerances for strip 4 and 8 ft. long
(1.22 m and 2.44 m)
between 0.5 in and 1.5 in (12.7 mm and 38.1 mm) wide
(diagram exaggerated for emphasis)


Back to Contents