Camber (edgebow or sweep)
Standard Camber Tolerances
Strip
WidthStandard
CamberEquivalent camber limits: in. (mm)
For various strip lengths: ft. (m)W
in.
(mm)tolerance
Ct, in/ft
(mm/m)8 4 6 10 12 16 20 (2.44) (1.22) (1.83) (3.05) (3.66) (4.88) (6.09) 0.5-1.50 0.50 0.125 0.281 0.781 1.125 2.0 3.125 (12.7-38.1) (12.7) (3.18) (7.14) (19.84) (28.58) (50.8) (79.38) 1.5-13.0 .25 .0625 0.141 0.391 0.563 1.0 1.562 (38.1-330.2) (6.35) (1.59) (3.58) (9.93) (14.30) (25.4) (39.68) If camber is measured over a strip length not shown in table above, it can be easily converted to an equivalent value for comparison with the standard tolerance, using the formula:
| Cu = Ck | x (Lu / Lk)2 |
| where | Cu = Unknown Camber |
| Ck = Known Camber | |
| Lu = Unknown Length | |
| Lk = Known Length |
Standard Camber Tolerances for strip
4 and 8 ft. long
(1.22 m and 2.44 m)
between 0.5 in and 1.5 in (12.7 mm
and 38.1 mm) wide
(diagram exaggerated for emphasis)
Back to Contents